==Economic==
The main economic costs come from the installation and operation of environmental control equipment.[4] These costs are of separation equipment, such as settling tanks, electrostatic precipitators, and distillation columns, as well as disposal equipment, such as incinerators and reactors that neutralize or oxidize a waste stream. Another cost that companies must incur is that of the removal of these wastes. Companies will often pay third party waste management companies to take waste streams and dispose of them, through means such as burial and placing in a landfill, for example. There are also the costs of cooling towers and noise abatement measures to take into consideration.
The main economic costs come from the installation and operation of environmental control equipment [4]. These costs are of separation equipment, such as settling tanks, electrostatic precipitators, and distillation columns, as well as disposal equipment, such as incinerators and reactors that neutralize or oxidize a waste stream. Another cost that companies must incur is that of the removal of these wastes. Companies will often pay third party waste management companies to take waste streams and dispose of them, through means such as burial and placing in a landfill, for example. There are also the costs of cooling towers and noise abatement measures to take into consideration.


The cost of not taking the environment into consideration when designing a process can far outreach that of the equipment, however. If a company does not follow regulations, they incur legal expenses as a penalty. Additionally, failure to comply can a high cost associated with poor public perception of the company. Bad press and public protests can lead to a large loss in profit. [5]
The cost of not taking the environment into consideration when designing a process can far outreach that of the equipment, however. If a company does not follow regulations, they incur legal expenses as a penalty. Additionally, failure to comply can a high cost associated with poor public perception of the company. Bad press and public protests can lead to a large loss in profit [5].


In the long run, it can often be in a company's best interest to take environmental factors into consideration. Optimizing a process, to reduce waste, results in less money that needs to be spent on waste disposal. Additionally, using recycle streams effectively may reduce the cost of the inputs to the process. Finally, if a process is designed in such a way that the waste streams are actually desired by another company, there is actual profit that can be made through the sale of this “engineering scrap.”[6]
In the long run, it can often be in a company's best interest to take environmental factors into consideration. Optimizing a process, to reduce waste, results in less money that needs to be spent on waste disposal. Additionally, using recycle streams effectively may reduce the cost of the inputs to the process. Finally, if a process is designed in such a way that the waste streams are actually desired by another company, there is actual profit that can be made through the sale of this “engineering scrap.”[6]
Line 33: Line 33:


==Noise Pollution==
==Noise Pollution==
Noise pollution is any unwanted or disturbing sound that diminished quality of life [7].

===Causes & Effects===
===Causes & Effects===
Equipment that are likely to be noisy are compressors, fans, burners, and steam relief valves [1]. Whereas this unwanted noise may often be considered just an annoyance, there are studies that link elevated noise to health issues. For example, being exposed to unwanted noise can lead to an increase in stress and disruption of sleep, thus leading to increased blood pressure. Exposure to high levels of sound can lead to Noise-Induced Hearing Loss (NIHL) [1].

===Treatment===
===Treatment===
To mitigate the adverse human effects of noise pollution, the EPA has included provisions in the Clean Air Act, the noise Control Act of 1972 and the Quiet Communities Act of 1978. However, the responsibility of noise control is mainly handled at the State and local level [7].

Some design decisions can be made to reduce the effects of noise on humans. Noisy equipment should not be placed near rooms that are often occupied. Additionally, rooms can be insulated to mitigate the length which the noise travels. If workers are to be near noise, they should wear earplugs to reduce the impact. Finally, choosing a plant location that is far from communities will reduce the amount of people exposed to any loud noises.


==Thermal Pollution==
==Thermal Pollution==
Thermal pollution relates to the heat released by a plant into the environment. This often comes from water that was used to cool down a process and then released into the environment.

===Causes & Effects===
===Causes & Effects===
The largest concern with regards to thermal pollution is water quality. The temperature of water directly relates factors such as density, surface tension, and to the solubility of gases in the water. The most important consideration is the solubility of oxygen in water. Dissolved oxygen in water is essential in maintaining aquatic life. Thus changing the temperature of water due to thermal pollution can alter water ecosystems. An additional concern is that increased water temperatures lead to a reduction in capacity for organic wastes assimilation.

===Treatment===
===Treatment===
Because of the negative effects of thermal pollution, and federal water temperature standards, design engineers must employ the use of various process technologies to mitigate thermal pollution. Options for reducing temperatures of water streams are: cooling towers, cooling ponds, and spray ponds. All of these technologies use the principles of heat transfer across a water-air interface, thus the heat from the water is transferred to air, which can be released into the environment. Another consideration is to recycle the heat. Hot water or fluid waste/effluent streams can be used in a heat exchange network to transfer heat to an inlet stream that requires heating before entering a process.

==Air Pollution==
Air pollutants can be either gases or particulate matter suspended in an effluent air stream. Some examples are: CO2, sulfates, nitrates, particulates (PM10, PM2.5), Volatile Organic Compounds (VOC) and, less commonly, chlorine compounds [1].


==Gas==
===Causes & Effects===
===Causes & Effects===
Gas pollutants often come from fired heaters, boilers or flares in the form of CO2 or other sulfates and nitrates, particulates (PM10, PM2.5), Volatile Organic Compounds (VOC) and, less commonly, chlorine compounds [1]. These gaseous wastes are often under careful scrutiny from governments as well as the public since gases being released from towers are often the easiest forms of pollution for a casual observer to see.
These pollutants often come from fired heaters, boilers or flares. These wastes are often under careful scrutiny from governments as well as the public since gases being released from towers are often the easiest forms of pollution for a casual observer to see.


Gas emissions can be particularly dangerous because left unchecked they can have far reaching consequences. Historically, the main focal points for gas emissions have been the effects on acid rain, ozone and greenhouse gases. Lately, greenhouse gases have been the most scrutinized due to growing concerns of global warming.
Emissions to the air can be particularly dangerous because, if left unchecked, they can have far reaching consequences. Historically, the focal points for air emissions have been the effects on acid rain, ozone and greenhouse gases. Lately, greenhouse gases have been the most scrutinized due to growing concerns of global warming.


===Treatment===
===Treatment===
Gaseous wastes must be treated before being released into the atmosphere, especially given the recent emphasis on green processes and the growing alarm with regards to global warming. Due to the properties of gases, air pollution can be the most expensive and energy intensive. Noxious elements can often be removed by absorption or adsorption, which are the most common ways to treat gaseous wastes. Typically, there are two main classifications of air pollution control equipment: those that can physically remove particles and those associated with removing gaseous pollutants. Figure 3 compares the size and type of common particles to the method of particle analysis and appropriate cleaning equipment [4].
Air emissions must be treated before being released into the atmosphere, especially given the recent emphasis on green processes and the growing alarm with regards to global warming. Due to the properties of gases, air pollution control can be the most expensive and energy intensive. Typically, there are two main classifications of air pollution control equipment: those associated with removing gaseous pollutants from streams to be released into the air and those that can physically remove particles from these streams.


Equipment chosen to remove a gaseous pollutant depends on whether the gas is easily reacted into something that is less harmful to the environment. Noxious elements are often removed by absorption, using a gas scrubber which utilizes a liquid solvent, or by adsorption, using a gas adsorber utilizing either a liquid or solid as the adsorber for the pollutant being removed. An important note is that these pieces of equipment often do not render the pollutant harmless, but simply change the form from gas to liquid or from gas to solid, both of which needs further treatment. For those pollutants which can be reacted into something less harmful, equipment such as reactors and incinerators are used. For example, combustible vapors are often burned in either a direct incinerator or in a catalytic incinerator, to increase the efficiency of the burning reaction. However, these incinerators often require very high operating costs.
'''Figure 2:'''

For the removal of particles from gas streams, there is a wide variety of possible equipment, chosen based on particle size and characteristics, as shown in Figure 1 below.[5] Mechanical collectors are generally used when particle sizes are large. Some mechanical collection equipment are: settling chambers, which are driven by gravity; cyclones, which make use of centrifugal forces; and bag filters, which collect particles from the gas by interception on the fabric surface of the bag.[7] Mechanical collectors are all dry methods of particle removal. There are also a variety of wet methods that can be employed to rid gases of particles. Wet methods such as a spray tower and Venturi scrubber rely on the collision of the particles with water to remove the particles from the gas. A final method of particulate removal is an electrostatic precipitator (ESP). An ESP will charge the particles in the gas by applying a high voltage, then allow these charged particles to be attracted to oppositely charged collection plates.[5] ESPs are useful for removing ultra-fine particles from corrosive gas streams, but are often sensitive to the properties of the particle. Additionally, the method of using rapping to remove the particles from the collection plates is rudimentary and often causes maintenance issues.[7]

'''Figure 1:'''


[[File:air_particles.png]]
[[File:air_particles.png]]


==Liquid==
==Water Pollution==
Types of water pollutants are: chemicals, such as oil; suspended solids, such as metals and biological materials; and dissolved (aqueous) materials, such as ions.

===Causes & Effects===
===Causes & Effects===
Water pollution typically comes from three streams: process waste, utility waste and run-off streams. Process waste streams are the unwanted side products of reactions and include salt water, hydrocarbon contaminated water, biologically contaminated water, and water with too high or low pH. Utility waste is mainly produced from cooling tower water blowdown. The purpose of blowdown is to prevent a buildup of salts in the towers, but produces a stream of contaminated water. Finally, run-off streams come from rain water, hydrant flushing and equipment washing.
Water pollution typically comes from three streams: process waste, utility waste and run-off streams. Process waste streams are the unwanted side products of reactions and include salt water, hydrocarbon contaminated water, biologically contaminated water, and water with too high or low pH. Utility waste is mainly produced from cooling tower water blowdown. The purpose of blowdown is to prevent a buildup of salts in the towers, but produces a stream of contaminated water. Finally, run-off streams come from rain water, hydrant flushing and equipment washing.


Liquid wastes are typically not as far reaching as gaseous waste, but can be much more devastating. Ecosystems can be destroyed from lax wastewater policies. Local populations can suffer from a lack of clean drinking water or dying wildlife in the area. The BP oil spill was a highly visible incident that showed how much damage can be done by water borne pollutants.
Liquid wastes are typically not as far reaching as gaseous waste, but can be much more devastating. Ecosystems can be destroyed from poor wastewater policies. Local populations can suffer from a lack of clean drinking water or dying wildlife in the area. The BP oil spill was a highly visible incident that showed how much damage can be done by water borne pollutants.

Aqueous wastes can be the most immediately harmful to the environment and people living nearby and must be sent immediately to an effluent treatment. Some of the most common, harmful water contaminants are ammonia, salts from deionizers, hydrocarbons, spent acids, caustics, and various forms of biological contamination. Utilities on-site can also create large wastewater flows that must be purged in order to prevent solid buildups. The most efficient way to deal with contaminated runoff is to collect and purify it on-site before disposing of it [3].


===Treatment===
===Treatment===
Line 64: Line 86:
Liquid wastes are usually flammable and can be burned in an incinerator as long as care is taken to insure the temperatures are high enough to destroy the harmful compounds. This only shifts the problem, however, as it creates gaseous wastes.
Liquid wastes are usually flammable and can be burned in an incinerator as long as care is taken to insure the temperatures are high enough to destroy the harmful compounds. This only shifts the problem, however, as it creates gaseous wastes.


Wastewater that contains large particles, either floating or suspended, will usually be first treated by simply skimming off or pulling out the large masses of particles. Following this, wastewater will be sent to a sedimentation basin to allow the particles to settle due to the force of gravity. The sludge that forms on the bottom of the basin is removed with sludge scrapers. For smaller particles that are not settled out of the water, a rapid sand filter or multimedia (usually sand and anthracite) filter can be used.[8] For very small particles, membrane processes can be employed. These include ultra-filtration, which uses exclusion of particles based on size, reverse osmosis, which excludes based on both size and particle properties, and electrodialysis, which is used to remove ionic species from the water.[5]
Aqueous wastes can be the most immediately harmful to the environment and people living nearby and must be sent immediately to an effluent treatment. Some of the most common, harmful water contaminants are ammonia, salts from deionizers, hydrocarbons, spent acids, caustics, and various forms of biological contamination. Utilities on-site can also create large wastewater flows that must be purged in order to prevent solid buildups. The most efficient way to deal with contaminated runoff is to collect and purify it on-site before disposing of it [3].

To treat water contaminated with organic matter, microorganisms can be used. The microorganisms break down the organic matter, either aerobically or anaerobically depending on the organism. Aerobic biological processes either used activated sludge, where biological growths are mixed in the wastewater and the resulting suspension is separated by gravity, or the fixed-film method, in which wastewater trickles over a biological film.[5]

Chemical treatment of water is generally used to remove color, odor, acids and alkalies, heavy metals, colloids, and oil. To remove colloids, coagulation is often used. In coagulation, chemicals are added to the water to break down the electrostatic double layer or the colloidal particles, essentially to neutralize the charge of the particles, allowing them to combine during flocculation.[8] To treat acid and alkaline waste, lime and sulfuric acid are often used.[5] Converse to this, distillation or salt precipitation methods can be used to recover the acid or alkali. To disinfect the water, chlorine or ozone are often used. Ozone, in addition to disinfection, is also useful for color, taste, and odor removal from the water.

==Land Pollution==
Land pollution is any solid wastes that requires disposal. Solid wastes are generally identified as flammable, toxic, corrosive or reactive. Waste containing any of these characteristics must be specially handled to ensure as little damage to the local environment as possible.


==Solid==
===Causes & Effects===
===Causes & Effects===
Left unchecked, large amounts of flammable waste could ignite and become very difficult to control. Toxic, corrosive or reactive materials have averse affects to any local populations, often causing major health problems in humans and animals alike. Solid waste in a landfill can create chemical leachates which, if improperly handled, can seep into the ground and into groundwater.
Solid, hazardous wastes are generally the easiest to control, but can also be the most difficult to safely discard; once created they can last much longer and do more damage than liquid or gaseous pollution. Table 1 below shows various types of solid wastes and how they can be treated. A more detailed description of solid waste treatment can be found in the Treatment section below.

===Treatment===
Solid, hazardous wastes are generally the easiest to control, but can also be the most difficult to safely discard; once created they can last much longer and do more damage than liquid or gaseous pollution. Table 1 below shows various types of solid wastes and how they can be treated.


'''Table 1:'''
'''Table 1:'''
Line 75: Line 106:
[1]
[1]


Table 1 shown above introduces several forms of solid waste disposal. The main types of disposal are recycling, chemical conversion, incineration, pyrolysis, and landfill. [5] Chemicals can be recovered from solids through extraction or stripping, while valuable solids can be recovered through a variety of methods such as flotation, electrical conductivity, or hand picking. Recycling these products or even selling them can often save company money in the long run. Chemical conversion of solid waste can often be used to convert the waste into something less harmful or sellable. Incineration is used to create a residue that is much smaller and more acceptable for landfill application. Incineration can be expensive, but if done properly can potentially recover some fuel value through the generation of steam. Pyrolysis, or the heating of the waste in an air-free chamber, is an alternative to incineration that avoids a lot of the air pollution issues associated with incineration. [5]
Solid wastes are generally identified as flammable, toxic, corrosive or reactive. Waste containing any of these characteristics must be specially handled to ensure as little damage to the local environment as possible. Left unchecked, large amounts of flammable waste could ignite and become very difficult to control. Toxic, corrosive or reactive materials have averse affects to any local populations and must also be disposed of with special care.


Landfills are useful for disposing large quantities of waste, but if the contents are legally classified as "hazardous", the waste must go through a pretreatment process in order to reduce the contaminants to an acceptable level. Additionally, proper lining of the landfill must be installed to prevent leachates that seep from the landfill and into groundwater.
===Treatment===
Figure 1 shown above introduces several forms of solid waste disposal. The four main types are incineration, landfills, land treatment and recycle. Incineration can be one of the more expensive, but if done properly can potentially recover some fuel value. Landfills are useful for disposing large quantities of waste, but if the contents are legally classified as "hazardous", the waste must go through a pretreatment process in order to reduce the contaminants to an acceptable level. Finally, recycle can be the most profitable solution instead of disposal if the waste can be reused in another capacity.


=Waste Minimization=
=Waste Minimization=

Revision as of 01:01, 6 February 2015


Authors: Sean Cabaniss, [2014] David Park, [2014] Maxim Slivinsky, [2014] Julianne Wagoner, [2014] and Michelle Spiezio [2015]

Steward: David Chen, Jian Gong, and Fengqi You

Date Presented: Feb. 23, 2014


Overview

All industrial processes produce waste in some form that must be carefully handled and disposed of according to regulations set down by governments at varying levels. The key areas for consideration are emissions to the land, air, and water, waste management, smells, noise, and visual impact. It is important to remember that pollution considerations are both a moral and legal obligation for any engineer or industry [1]. Emissions from chemical plants are regulated by both local and federal governments. Plants are required to monitor and document waste streams discharged to the environment, maintain permits from local governmental agencies, and either pay fines or directly address any violations [2].

Human Health, Social and Economic costs

Human Health

The human costs associated with chemical plant pollution come in the form of endangerment to the health of people in local communities. Because chemical plants are not going to be fully contained, it is necessary to determine how those streams and pollutants that are emitted affect the surrounding population. A few examples of this are: contamination of the local potable water supply if, for instance, chemicals in a retention pond leech out and into groundwater; release of particulate matter reducing the air quality of a community to the point where instances of asthma increase; and, the release of hazardous chemicals causing carcinogenic effects [3].

Social

The social costs linked to environmental concerns relate to the public perception of the company and its actions with regard to environmental stewardship. Any company that produces waste streams is going to be scrutinized by the public for the way these streams are handled. Companies caught or known for high pollution levels often receive bad press, which can also give investors a bad impression and hurt stock prices. A recent example of high social costs is the outcry in the wake of the BP oil spill. It is to the advantage of the company, therefore, to prove to the public that every effort is being made to responsibly handle waste streams.

Economic

The main economic costs come from the installation and operation of environmental control equipment [4]. These costs are of separation equipment, such as settling tanks, electrostatic precipitators, and distillation columns, as well as disposal equipment, such as incinerators and reactors that neutralize or oxidize a waste stream. Another cost that companies must incur is that of the removal of these wastes. Companies will often pay third party waste management companies to take waste streams and dispose of them, through means such as burial and placing in a landfill, for example. There are also the costs of cooling towers and noise abatement measures to take into consideration.

The cost of not taking the environment into consideration when designing a process can far outreach that of the equipment, however. If a company does not follow regulations, they incur legal expenses as a penalty. Additionally, failure to comply can a high cost associated with poor public perception of the company. Bad press and public protests can lead to a large loss in profit [5].

In the long run, it can often be in a company's best interest to take environmental factors into consideration. Optimizing a process, to reduce waste, results in less money that needs to be spent on waste disposal. Additionally, using recycle streams effectively may reduce the cost of the inputs to the process. Finally, if a process is designed in such a way that the waste streams are actually desired by another company, there is actual profit that can be made through the sale of this “engineering scrap.”[6]

Types of Pollution and Treatment

Noise Pollution

Noise pollution is any unwanted or disturbing sound that diminished quality of life [7].

Causes & Effects

Equipment that are likely to be noisy are compressors, fans, burners, and steam relief valves [1]. Whereas this unwanted noise may often be considered just an annoyance, there are studies that link elevated noise to health issues. For example, being exposed to unwanted noise can lead to an increase in stress and disruption of sleep, thus leading to increased blood pressure. Exposure to high levels of sound can lead to Noise-Induced Hearing Loss (NIHL) [1].

Treatment

To mitigate the adverse human effects of noise pollution, the EPA has included provisions in the Clean Air Act, the noise Control Act of 1972 and the Quiet Communities Act of 1978. However, the responsibility of noise control is mainly handled at the State and local level [7].

Some design decisions can be made to reduce the effects of noise on humans. Noisy equipment should not be placed near rooms that are often occupied. Additionally, rooms can be insulated to mitigate the length which the noise travels. If workers are to be near noise, they should wear earplugs to reduce the impact. Finally, choosing a plant location that is far from communities will reduce the amount of people exposed to any loud noises.

Thermal Pollution

Thermal pollution relates to the heat released by a plant into the environment. This often comes from water that was used to cool down a process and then released into the environment.

Causes & Effects

The largest concern with regards to thermal pollution is water quality. The temperature of water directly relates factors such as density, surface tension, and to the solubility of gases in the water. The most important consideration is the solubility of oxygen in water. Dissolved oxygen in water is essential in maintaining aquatic life. Thus changing the temperature of water due to thermal pollution can alter water ecosystems. An additional concern is that increased water temperatures lead to a reduction in capacity for organic wastes assimilation.

Treatment

Because of the negative effects of thermal pollution, and federal water temperature standards, design engineers must employ the use of various process technologies to mitigate thermal pollution. Options for reducing temperatures of water streams are: cooling towers, cooling ponds, and spray ponds. All of these technologies use the principles of heat transfer across a water-air interface, thus the heat from the water is transferred to air, which can be released into the environment. Another consideration is to recycle the heat. Hot water or fluid waste/effluent streams can be used in a heat exchange network to transfer heat to an inlet stream that requires heating before entering a process.

Air Pollution

Air pollutants can be either gases or particulate matter suspended in an effluent air stream. Some examples are: CO2, sulfates, nitrates, particulates (PM10, PM2.5), Volatile Organic Compounds (VOC) and, less commonly, chlorine compounds [1].

Causes & Effects

These pollutants often come from fired heaters, boilers or flares. These wastes are often under careful scrutiny from governments as well as the public since gases being released from towers are often the easiest forms of pollution for a casual observer to see.

Emissions to the air can be particularly dangerous because, if left unchecked, they can have far reaching consequences. Historically, the focal points for air emissions have been the effects on acid rain, ozone and greenhouse gases. Lately, greenhouse gases have been the most scrutinized due to growing concerns of global warming.

Treatment

Air emissions must be treated before being released into the atmosphere, especially given the recent emphasis on green processes and the growing alarm with regards to global warming. Due to the properties of gases, air pollution control can be the most expensive and energy intensive. Typically, there are two main classifications of air pollution control equipment: those associated with removing gaseous pollutants from streams to be released into the air and those that can physically remove particles from these streams.

Equipment chosen to remove a gaseous pollutant depends on whether the gas is easily reacted into something that is less harmful to the environment. Noxious elements are often removed by absorption, using a gas scrubber which utilizes a liquid solvent, or by adsorption, using a gas adsorber utilizing either a liquid or solid as the adsorber for the pollutant being removed. An important note is that these pieces of equipment often do not render the pollutant harmless, but simply change the form from gas to liquid or from gas to solid, both of which needs further treatment. For those pollutants which can be reacted into something less harmful, equipment such as reactors and incinerators are used. For example, combustible vapors are often burned in either a direct incinerator or in a catalytic incinerator, to increase the efficiency of the burning reaction. However, these incinerators often require very high operating costs.

For the removal of particles from gas streams, there is a wide variety of possible equipment, chosen based on particle size and characteristics, as shown in Figure 1 below.[5] Mechanical collectors are generally used when particle sizes are large. Some mechanical collection equipment are: settling chambers, which are driven by gravity; cyclones, which make use of centrifugal forces; and bag filters, which collect particles from the gas by interception on the fabric surface of the bag.[7] Mechanical collectors are all dry methods of particle removal. There are also a variety of wet methods that can be employed to rid gases of particles. Wet methods such as a spray tower and Venturi scrubber rely on the collision of the particles with water to remove the particles from the gas. A final method of particulate removal is an electrostatic precipitator (ESP). An ESP will charge the particles in the gas by applying a high voltage, then allow these charged particles to be attracted to oppositely charged collection plates.[5] ESPs are useful for removing ultra-fine particles from corrosive gas streams, but are often sensitive to the properties of the particle. Additionally, the method of using rapping to remove the particles from the collection plates is rudimentary and often causes maintenance issues.[7]

Figure 1:

Air particles.png

Water Pollution

Types of water pollutants are: chemicals, such as oil; suspended solids, such as metals and biological materials; and dissolved (aqueous) materials, such as ions.

Causes & Effects

Water pollution typically comes from three streams: process waste, utility waste and run-off streams. Process waste streams are the unwanted side products of reactions and include salt water, hydrocarbon contaminated water, biologically contaminated water, and water with too high or low pH. Utility waste is mainly produced from cooling tower water blowdown. The purpose of blowdown is to prevent a buildup of salts in the towers, but produces a stream of contaminated water. Finally, run-off streams come from rain water, hydrant flushing and equipment washing.

Liquid wastes are typically not as far reaching as gaseous waste, but can be much more devastating. Ecosystems can be destroyed from poor wastewater policies. Local populations can suffer from a lack of clean drinking water or dying wildlife in the area. The BP oil spill was a highly visible incident that showed how much damage can be done by water borne pollutants.

Aqueous wastes can be the most immediately harmful to the environment and people living nearby and must be sent immediately to an effluent treatment. Some of the most common, harmful water contaminants are ammonia, salts from deionizers, hydrocarbons, spent acids, caustics, and various forms of biological contamination. Utilities on-site can also create large wastewater flows that must be purged in order to prevent solid buildups. The most efficient way to deal with contaminated runoff is to collect and purify it on-site before disposing of it [3].

Treatment

The main factors that usually have some sort of legislative constraints are pH levels, suspended solids, toxicity, and biological oxygen demand. Oxygen demand is often under looked as a form of pollution because there is rarely visible evidence that something is wrong in the stream. However, many local governments mandate that the water leaving a plant must have enough oxygen to sustain aquatic life before being released.

Liquid wastes are usually flammable and can be burned in an incinerator as long as care is taken to insure the temperatures are high enough to destroy the harmful compounds. This only shifts the problem, however, as it creates gaseous wastes.

Wastewater that contains large particles, either floating or suspended, will usually be first treated by simply skimming off or pulling out the large masses of particles. Following this, wastewater will be sent to a sedimentation basin to allow the particles to settle due to the force of gravity. The sludge that forms on the bottom of the basin is removed with sludge scrapers. For smaller particles that are not settled out of the water, a rapid sand filter or multimedia (usually sand and anthracite) filter can be used.[8] For very small particles, membrane processes can be employed. These include ultra-filtration, which uses exclusion of particles based on size, reverse osmosis, which excludes based on both size and particle properties, and electrodialysis, which is used to remove ionic species from the water.[5]

To treat water contaminated with organic matter, microorganisms can be used. The microorganisms break down the organic matter, either aerobically or anaerobically depending on the organism. Aerobic biological processes either used activated sludge, where biological growths are mixed in the wastewater and the resulting suspension is separated by gravity, or the fixed-film method, in which wastewater trickles over a biological film.[5]

Chemical treatment of water is generally used to remove color, odor, acids and alkalies, heavy metals, colloids, and oil. To remove colloids, coagulation is often used. In coagulation, chemicals are added to the water to break down the electrostatic double layer or the colloidal particles, essentially to neutralize the charge of the particles, allowing them to combine during flocculation.[8] To treat acid and alkaline waste, lime and sulfuric acid are often used.[5] Converse to this, distillation or salt precipitation methods can be used to recover the acid or alkali. To disinfect the water, chlorine or ozone are often used. Ozone, in addition to disinfection, is also useful for color, taste, and odor removal from the water.

Land Pollution

Land pollution is any solid wastes that requires disposal. Solid wastes are generally identified as flammable, toxic, corrosive or reactive. Waste containing any of these characteristics must be specially handled to ensure as little damage to the local environment as possible.

Causes & Effects

Left unchecked, large amounts of flammable waste could ignite and become very difficult to control. Toxic, corrosive or reactive materials have averse affects to any local populations, often causing major health problems in humans and animals alike. Solid waste in a landfill can create chemical leachates which, if improperly handled, can seep into the ground and into groundwater.

Treatment

Solid, hazardous wastes are generally the easiest to control, but can also be the most difficult to safely discard; once created they can last much longer and do more damage than liquid or gaseous pollution. Table 1 below shows various types of solid wastes and how they can be treated.

Table 1:

Solid wastes.png [1]

Table 1 shown above introduces several forms of solid waste disposal. The main types of disposal are recycling, chemical conversion, incineration, pyrolysis, and landfill. [5] Chemicals can be recovered from solids through extraction or stripping, while valuable solids can be recovered through a variety of methods such as flotation, electrical conductivity, or hand picking. Recycling these products or even selling them can often save company money in the long run. Chemical conversion of solid waste can often be used to convert the waste into something less harmful or sellable. Incineration is used to create a residue that is much smaller and more acceptable for landfill application. Incineration can be expensive, but if done properly can potentially recover some fuel value through the generation of steam. Pyrolysis, or the heating of the waste in an air-free chamber, is an alternative to incineration that avoids a lot of the air pollution issues associated with incineration. [5]

Landfills are useful for disposing large quantities of waste, but if the contents are legally classified as "hazardous", the waste must go through a pretreatment process in order to reduce the contaminants to an acceptable level. Additionally, proper lining of the landfill must be installed to prevent leachates that seep from the landfill and into groundwater.

Waste Minimization

Chemical engineers need to keep several environmental considerations in mind when designing processes. During the design of the process, the toxicities of all the products, byproducts, and wastes produced by the system must be considered. Then, the reaction pathway that minimizes toxic components should be chosen whenever possible. A good design will seek to minimize, recycle, and make use of segregated waste streams in order to satisfy the demands of the waste market [3]. Optimization is a powerful tool for waste minimization because it cuts down on toxic materials as well as improving the overall system. Optimization can be used to account for environmental impact, such as the effects of carbon monoxide or other greenhouse gases. The general 5-step process for waste minimization can be summarized as: 1) Identify waste components for regulatory impact. 2) Identify waste streams for size and economic impact. 3) List the root causes of the waste streams. 4) List and analyze modifications to address the root causes. 5) Prioritize and implement the best solutions [1].

Legislative Action

1972 Federal Water Pollution Control Act

The US Water Pollution Control Act set forth three major new regulations in an effort to keep toxic contaminants from getting into water supplies. Its goal was to achieve clean water for swimming, boating, and protecting fish and wildlife by 1983. This legislation said the EPA would set water quality standards for pollutants in surface water, set effluent guidelines for each industrial sector, and that it is unlawful to discharge any pollutant into navigable waters without a permit. [5]

Resource Conservation and Recovery Act (RCRA)

The ultimate goal of this act is to protect the groundwater from contamination. The act addressed waste management from "cradle to grave". It identified wastes on regulatory lists or if it has a certain characteristic level of flammability, toxicity, corrosivity, or reactivity. The act also specified how hazardous wastes must be labeled and tracked in transport as well as the treatments required for low levels of contaminants. [6]

Example Environmental Design Problem

Volatile Organic Compound Abatement [4]

The 1990 Clean Air Act mandates a reduction in emissions of volatile organic compounds (VOC). Any VOC emission sources exceeding 10tons/year must retrofit abatement processes with the best available control technology (BACT).

A paint spraying plant emits VOCs from vents in the paint spray booths. The stream contains primarily toluene, methyl ethyl ketone (MEK), and xylene, with small impurities of silicone and phosphorus. The concentration of VOCs in the dryer effluent varies between a minimum of 0.3 wt% VOC and a maximum of 1.2 wt% VOC with an approximate composition of 50% toluene, 25% MEK, and 25% xylene.

The painting company has commissioned you to evaluate three different technologies for a reduction in VOCs: thermal incineration, catalytic incineration, and carbon absorption and destruction of the VOCs. The low quality steam can be used by a nearby bottle washing plant.

Design an emission control plant for 50,000 scfm of vent gas at 100F and 25% relative humidity for 99% removal. The plant is located in Dearborn, Michigan, and the paint spray booths operate on a single 12-hour shift per day. Include the necessary start-up controls. The available fuel is natural gas or oil. Calculate the capital and operating cost and the $/lb or ton of VOC removed. Compare the three processes and recommend which is most suitable for this application.

Conclusion

Nearly all industrial chemical processes have pollution in one form or another. There are several sources and compounds of waste in all phases to be aware of and to know how to dispose of properly. A proper understanding of these hazardous compounds and materials as well as the effects these pollutants can have is essential, especially as an engineer. A chemical engineer's duty is to ensure that the waste, whether a gas, liquid, or sold is disposed of or recycled in a responsible manner and according to the local and federal guidelines. Proper waste management not only reflects well on a company and its engineers, but also can have lasting benefits to profits and the wellbeing of locals in the area. On the other hand, reckless waste handling policies are not only dangerous for a plant and those around it, but are in danger of serious repercussions from the government and in the EPA. Finally, engineers have a moral obligation to uphold certain standards even when working in countries with less strict waste management standards.

References

  1. Towler, G.P. and Sinnot, R. (2012). Chemical Engineering Design: Principles, Practice and Economics of Plant and Process Design. Elsevier.
  2. Towler, G.P. (2012). Chemical Engineering Design, PowerPoint presentation.
  3. Seider, W.D. (2004). Process Design Principles: Synthesis, Analysis, and Evaluation, Wiley: New York.
  4. E. Robert Becker, "Volatile Organic Compound Abatement", Environex, January 1994 (DELETE)
  5. U.S. Government page "Digest of Federal Resource Laws of Interest to the U.S. Fish and Wildlife Service" Digest of Federal Resource Laws of Interest to the U.S. Fish and Wildlife Service
  6. EPA Website "Resource Conservation and Recovery Act (RCRA)" http://www.epa.gov/agriculture/lrca.html